MYJG200W CO2 laser power supply
Model NO.MYJG 200W
- Unit Price
- US$ 139.00
- Min.Order
- 1 Piece/Pieces
- Category
- MYJG200W Co2 Laser Power Supply
- Brand
- ZYE
- Place of Origin
- Shandong,China
- Certification
- ISO,CE
- Supply Ability
- 20,000 piece per month
- Packaging
- 1 piece per small carton,2 pieces per large carton
- Port
- Q,i,n
Keywords
Product Attributes
| Min. Order | 1 Piece/Pieces |
|---|---|
| Transportation | Ocean,Land,Air,Express |
| Port | Q,i,n |
| Model No. | MYJG 200W |
| Brand | ZYE |
Supply Ability & Additional Information
| Packaging | 1 piece per small carton,2 pieces per large carton |
|---|---|
| Productivity | 20,000 piece per month |
| Transportation | Ocean,Land,Air,Express |
| Place of Origin | Shandong,China |
| Supply Ability | 20,000 piece per month |
| Certificate | ISO,CE |
| HS Code | 8504401990 |
| Port | Q,i,n |
Packaging & Delivery
Product Description
The MYJG200W is a high-voltage power supply designed for technically matched 200W CO2 glass laser tube systems.
It provides a maximum output voltage of 45kV and a maximum output current of 45mA.
Instead of selecting a laser power supply only by wattage, the MYJG200W allows machine manufacturers and service technicians to check the laser-enable signal, 0–5V power-control input, water-protection circuit and current-monitoring configuration before installation.

Designed for Control and Current Monitoring
For CO2 laser machine production and maintenance, electrical-control compatibility is as important as the rated power.
The MYJG200W provides interfaces for:
High-level laser emission control
Low-level laser emission control
Water-protection input
Signal ground
0–5V laser power control
5V auxiliary output
Laser signal indication
Water-protection indication
External current-display connection
These interfaces allow the power supply to be checked against the machine controller before wiring.

The MYJG200W provides:
Maximum Voltage Output: 45kV
Maximum Current Output: 45mA
The 45mA value is the maximum output-current specification of the power supply.
Actual operating current should be set according to the requirements of the matched CO2 laser tube. Different laser tubes may require different working-current settings.
0–5V Laser Power Adjustment
The IN terminal provides a 0-5V laser power-control input.
This allows the laser output level to be controlled through the machine control system.
Before connection, technicians should check:
Controller signal type
Signal-ground definition
Control-voltage range
Terminal assignment
Do not assume that different laser controllers use identical wiring.
High / Low Laser Enable Control
The power supply supports both high-level and low-level laser emission control.
Confirmed control levels are:
Control Level
High Level ≥3V
Low Level ≤0.7V
This provides flexibility when matching the power supply with different CO2 laser machine control systems.
Water Protection Input
The MYJG200W includes a water-protection input for connection with the laser machine cooling-water protection circuit.
The water-cooling system and protection circuit should be checked before laser operation.
Correct cooling is especially important for higher-power CO2 glass laser tubes.
Why Choose ZYE Laser?
At ZYE Laser, we produce high-quality and easy-to-use CO2 laser power supplies designed for precision and durability. As a specialist factory in the laser technology industry, we focus on providing reliable power solutions to meet the needs of a wide range of applications.
Our team of professional engineers and skilled workers ensure that each product is meticulously crafted, guaranteeing consistent performance and longevity. By combining expertise with cutting-edge manufacturing processes, we are able to deliver innovative solutions that meet the highest standards and enable businesses to operate more efficiently.
Please don't hesitate to contact us if any interest.


FAQ
Q1. What are the maximum output specifications of MYJG200W?
The maximum output voltage is 45kV and the maximum output current is 45mA.
Q2. Is 45mA the normal working current?
No. 45mA is the maximum power-supply output specification. Actual operating current should follow the laser tube requirements.
Q3. Does MYJG200W support 0–5V power control?
Yes. The control interface includes a 0–5V laser power-control input.
Q4. Does it support both high- and low-level laser control?
Yes. The interface includes H and L laser-enable terminals. The documented control levels are ≥3V for high level and ≤0.7V for low level.
Q5. Does it have a water-protection input?
Yes. A water-protection input is included in the control interface.
Q6. Should I order AC110V or AC220V?
Please specify the AC input voltage used by your machine when ordering.
AC110V and AC220V are listed as input options. Do not assume automatic voltage switching.
Q8. Can MYJG200W directly replace another 200W power supply?
Not necessarily. Please compare the output parameters, control terminals, dimensions and high-voltage connection first. CAT